Multi -Roof Replacement Project
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
PRINCETON LAB - DOE CONTRACTOR
Contract Value
Not provided
Codes & Classification
Solicitation Number
RFP26-021R
NAICS
236220 - Commercial and Institutional Building Construction
Classification Code
Y1EZ
Additional Details
The Department of Energy, through its Princeton Laboratory (DOE Contractor), has issued a solicitation (RFP26-021R) for a comprehensive Multi-Roof Replacement Project at its Princeton, New Jersey facility. This procurement seeks qualified contractors to undertake the replacement of several aging roofs that are critical to the laboratory’s ongoing experimental operations. The affected buildings include the C50 ESAT Building, C52 PLT Power Building, C60 C Site Pump House, and D45 Rad Waste Handling Facility. These roofs have surpassed their useful life, resulting in frequent water infiltration, structural damage, and increased maintenance costs. The project’s successful completion is essential to safeguarding the laboratory’s infrastructure and ensuring uninterrupted research activities.
The scope of work encompasses the full removal and replacement of existing built-up roofing systems on the specified buildings. Contractors are required to provide all necessary materials, labor, supervision, equipment, and expertise to execute the project in accordance with detailed contract documents. Key tasks include demolition and disposal of old roofing materials (membrane, insulation, metal trim, flashing, coping, and accessories), recycling of stone ballast with proper documentation, and inspection and replacement of integrated roof elements such as wood blocking, roof drains, gutters, scuppers, downspouts, and roof panels.
The new roof system must utilize Carlisle Syntec Systems materials, specifically a 145 mil Fleeceback EPDM membrane (black, adhered to coverboard), two layers of 2.6” ISO insulation, and a ½” HD coverboard mechanically fastened. The system must achieve a minimum R-30 average insulating value, necessitating modifications to the building envelope. Additional deliverables include installation of flexible walkway pads, counter flashing, copings, expansion joints, roof perimeter guardrails, new and higher curbs, built-up roof vents, raised expansion joints, new roof drains and scuppers, and a minimum 12” overlap between adjacent roof membrane systems with written compatibility confirmation. All materials and installation must meet manufacturer specifications to secure a minimum 30-year manufacturer system warranty and a 2-year installer’s warranty, covering incidental punctures, hail damage, and wind gusts up to 72 mph.
Contractors are also responsible for the temporary relocation and reinstallation of fall protection anchor systems, installation of secondary drainage per code for the PLT building, and coordination with PPPL for asbestos abatement and equipment power disconnects. All roof fans and equipment must be salvaged, protected, and reinstalled. Coordination with PPPL is required throughout the project, especially for activities involving hazardous materials or equipment shutdowns.
This solicitation is classified under NAICS Code 236220 (Commercial and Institutional Building Construction) and Product Service Code Y1EZ. There are no set-aside requirements, making the opportunity open to all qualified contractors. The place of performance is Princeton, New Jersey, United States. The contracting entity is the Princeton Laboratory, a federal office under the Department of Energy. Interested parties should direct inquiries to Jimmy Russell at [email protected] or 609-243-3963.
The solicitation is active, with a posting date of January 28, 2026, and a response deadline of February 27, 2026. Contractors are advised to review all five cover letter sections and associated attachments, which are accessible via the provided SAM.gov link. Attachments must be downloaded and viewed using Adobe Acrobat to ensure access to all relevant project documentation.
This project represents a significant opportunity for contractors specializing in commercial and institutional roofing, particularly those with experience in complex federal facility environments and stringent warranty requirements. The scope, technical specifications, and coordination needs will remain consistent throughout the contract lifecycle, making this a stable and well-defined engagement for qualified bidders.
Documents9