The Department of Veterans Affairs (VA), through its Network Contract Office 01 (NCO 01), is soliciting quotations from qualified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) for the replacement of a failed C-2 heat exchanger at the White River Junction VA Medical Center (WRJVAMC) in Vermont. This procurement, identified under solicitation number 36C24126Q0170, is issued as a Combined Synopsis/Solicitation in accordance with Federal Acquisition Regulation (FAR) subpart 12.6, utilizing streamlined procedures for commercial products and services. The opportunity is active and responses are due by January 23, 2026, at 5:00 PM EST.
**Purpose and Scope**
The primary objective of this contract is to restore reliable HVAC functionality in Building 1, mechanical room 14, by replacing the failed C-2 heat exchanger and associated components. The heat exchanger is integral to the facility’s HVAC system, which supplies filtered fresh air to patient areas, directly impacting the health and comfort of veterans and staff. The scope encompasses removal and disposal of the existing heat exchanger, air separator, flash tank, and all non-compliant or unserviceable piping, pipe connections, and valves. The contractor will salvage and reinstall two circulator pumps, install new equipment (heat exchanger, air separator with auto vent, flash tank), reconfigure piping and fittings, insulate all new installations, and perform functional testing and system startup.
**Key Requirements and Deliverables**
- **Technical Specifications:** The replacement heat exchanger and components must be equivalent to the original equipment, meeting operational conditions as documented in the facility’s as-built drawings and nameplate data.
- **Contractor Qualifications:** All work must be performed by licensed pipefitters and qualified technicians with at least one year of relevant trade school and five years of experience in institutional or industrial plumbing/HVAC systems. Familiarity with NFPA 85, VHA Boiler Safety Manual, TEMA standards, and ASME code is required.
- **Service Provisions:** The contractor is responsible for providing all labor, equipment, materials, supervision, and transportation necessary for the project. Compliance with VA lock out/tag out procedures and infection control measures (ICRA) is mandatory. Construction debris must be managed per VA requirements, including use of sealed dump carts and approved debris removal pathways.
- **Submittals and Approvals:** All technical submittals must be reviewed and approved by the VA prior to commencement of work.
- **Work Schedule:** Work is to be performed during normal business hours (7:30 AM to 3:30 PM, Monday through Friday), with exceptions only for emergencies and with prior approval. The contractor must notify facility management and the Contracting Officer’s Representative (COR) at least two weeks before starting onsite work.
- **Information Security and Privacy:** While no direct connection to VA IT systems is involved, contractors must adhere to all VA privacy and federal records management policies, ensuring protection and proper handling of any incidental exposure to protected health information.
- **Period of Performance:** The contract period shall not exceed 80 days from notice to proceed.
**Contracting Entity and Location**
- **Contracting Office:** 241-NETWORK CONTRACT OFFICE 01 (NCO 01), Department of Veterans Affairs
- **Place of Performance:** White River Junction VA Medical Center, 163 Veterans Drive, White River Junction, VT 05009, United States
**Classification and Codes**
- **NAICS Code:** 238220 (Plumbing, Heating, and Air-Conditioning Contractors), small business size standard $19 million
- **Product Service Code (PSC):** J045
**Procurement Type and Set-Aside**
This solicitation is a total set-aside for SDVOSBs, in accordance with VAAR 852.219-73 and 852.219-75, with strict limitations on subcontracting. Only verified SDVOSBs are eligible to submit quotations.
**Submission and Evaluation**
Interested vendors must submit:
- A firm fixed price quote
- A completed and signed Limitation of Subcontracting certificate
- A technical capability statement or descriptive literature demonstrating compliance with the Statement of Work
Quotes must be clearly indexed, logically assembled, and include a statement of acceptance (or exceptions) to the solicitation’s terms and conditions. All submissions are to be sent electronically to Kenya R Mitchell at [email protected]. Questions must be submitted in writing by January 13, 2026, and a site visit is scheduled for January 14, 2026, at 9:00 AM (check-in at Building 37, POC: Scott Snyder).
Award will be made based on a comparative evaluation of technical capability, past performance, and price, in accordance with FAR 13.106-2(b)(3). The government reserves the right to select a quotation that offers the best value, not necessarily the lowest price, provided it meets or exceeds the minimum requirements.
**Contact Information**
- **Primary Contact:** Kenya R Mitchell
- **Email:** [email protected]
- **Phone:** 860-666-6951
**Additional Considerations**
Contractors must be registered in SAM.gov at the time of submission and comply with all applicable FAR and VAAR clauses, including those related to equal opportunity, labor standards, and restrictions on foreign purchases. The full solicitation and amendments are available at https://sam.gov/opp/c7874aa3b53e47fd8805c190b41a00cc/view.
**Summary**
This opportunity represents a critical infrastructure upgrade for the White River Junction VA Medical Center, requiring specialized HVAC and plumbing expertise, strict adherence to VA standards, and a commitment to minimizing disruption to healthcare operations. Qualified SDVOSBs with relevant experience and capacity are encouraged to review the detailed Statement of Work and submit a comprehensive quotation by the specified deadline.