F108--Air Quality Testing
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
VETERANS BENEFITS ADMIN (36C10D)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C10D26Q0011
NAICS
562910 - Remediation Services
Classification Code
F108
Additional Details
Documents5
The Department of Veterans Affairs, through its Veterans Benefits Administration, has issued a solicitation (Procurement Identifier: 36C10D26Q0011) for comprehensive environmental testing and inspection services at the Jackson VA Regional Office, located at 1600 East Woodrow Wilson Ave, Jackson, Mississippi, 39216. This procurement addresses an urgent requirement to assess and document potential mold and mildew contamination within the facility, which spans approximately 86,091 square feet. The impetus for this action stems from health concerns among building occupants related to possible indoor air quality issues.
The primary objective of this contract is to obtain detailed testing and inspection data that will inform a mold remediation plan for the Regional Office. The contractor will be responsible for providing all necessary labor, tools, materials, equipment, and supervision to execute the full scope of work as outlined in the Statement of Work (SOW). The period of performance is set at fourteen (14) days from the award of the purchase order, underscoring the urgency of the requirement.
Key tasks include a thorough visual inspection of the entire facility, utilizing moisture meters to detect hidden dampness, and collecting both air and surface samples from areas suspected of mold contamination. Air samples are to be analyzed in a laboratory to determine the type and concentration of mold present, with at least one exterior air sample collected to establish baseline environmental conditions. Surface samples may be collected via tape lift, swab, or contact plate, as deemed necessary by the assessor, to identify specific fungal genera. The sampling methodology must encompass a combination of air sampling techniques to provide a comprehensive assessment of the facility’s air quality. Analytical methods should include identification and enumeration of fungi through both non-viable and culturable samples, as well as quantitative polymerase chain reaction (qPCR) where appropriate.
The contractor is expected to deliver a detailed report summarizing all findings, identifying potential sources of moisture, and providing recommendations for remediation if warranted. Accuracy in measurement and documentation is critical, as the contractor will be held accountable for the precision of all data collected.
Offerors are required to demonstrate, in narrative form, their technical approach and qualifications, specifically addressing how they will meet or exceed all performance requirements. This includes discussing potential technical challenges, relevant specialized experience, and technical competence in environmental testing. Additionally, offerors must describe their capacity to marshal the necessary resources—such as funding, subcontractors, subject-matter experts, and specialized trades—to successfully complete the project. Importantly, the contractor must be a certified air quality professional.
This procurement is classified under NAICS Code 562910 (Remediation Services), with Product Service Code F108. The contracting entity is the Veterans Benefits Administration, a federal office within the Department of Veterans Affairs. The primary point of contact for this solicitation is Tiffany L Garfield, who can be reached at [email protected].
The solicitation is currently active, with a posting date of April 3, 2026, and responses due by October 3, 2026, at 16:03. Interested parties can access the full solicitation and associated attachments via the SAM.gov opportunity listing (Opportunity ID: dc12c5ca160d471fa6cd59102ed2cebb).
This opportunity is well-suited for contractors with proven expertise in environmental testing, particularly those with experience in large-scale mold and mildew assessments for institutional or government facilities. The short period of performance and the requirement for certified air quality professionals are critical considerations for prospective offerors.