Tiny Home
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
W6QM MICC-FT DRUM
Contract Value
Not provided
Codes & Classification
Solicitation Number
W911S226U2309
NAICS
321991 - Manufactured Home (Mobile Home) Manufacturing
Classification Code
5450
Additional Details
The U.S. Army, through the Mission and Installation Contracting Command at Fort Drum (W6QM MICC-FT DRUM), has issued a Combined Synopsis/Solicitation for the procurement of a prebuilt modular tiny home, classified under NAICS Code 321991 (Manufactured Home Manufacturing). This opportunity is set aside for Small Business Administration (SBA) eligible contractors, reflecting the government’s commitment to supporting small business participation in federal contracting.
**Purpose and Scope:**
The primary objective of this procurement is to acquire a modular home designed for four-season use, with robust fire protection and life safety systems, to serve as personnel housing or similar lodging facilities. The home must be prebuilt and delivered with a screened-in outdoor porch, and its exterior dimensions are strictly limited to 13 feet 8 inches by 39 feet 7 inches. The entrance will be accessed via the porch, and the structure must be anchored to an existing reinforced concrete slab, with piers constructed from CMU blocks and I-beams for support.
**Key Requirements and Deliverables:**
The contractor is responsible for providing a turnkey solution, including all materials, labor, and design services necessary to deliver a fully functional modular home. Notable requirements include:
- **Exterior Features:** Standing seam metal roof (5:12 pitch, factory finish), engineered wood lap siding and trims, LED outdoor lighting, insulated single-hung low E vinyl windows, lockable steel entry door with smart programmable lock, insulated skirting (R11 or greater), and access door for underbelly maintenance.
- **Interior Features:** Full kitchen (stainless steel appliances, granite countertops, tile backsplash, soft-close cabinetry), full bathroom (tile shower, glass door, rainfall and handheld shower heads, comfort height toilet), split system heating/cooling units for master bedroom and living area, smooth finished ceilings (9-10 feet), vinyl plank flooring, solid wood trim, furniture package (sectional sofa, beds, mattresses, dressers, nightstands, wall-mounted TVs), ceiling fan with LED lights, USB-C outlets, and on-demand gas water heater.
- **Fire Protection and Life Safety:** Comprehensive fire protection systems are mandatory, including sprinkler and fire alarm systems designed and installed in accordance with UFC 3-600-01, UFC 4-021-01, NFPA 13R, NFPA 24, NFPA 70, NFPA 72, NFPA 101, NFPA 90A, NFPA 10, and related standards. The contractor must engage a qualified Fire Protection Engineer (FPE)—a registered P.E. with at least five years of dedicated fire protection engineering experience—to oversee all aspects of fire protection design, construction, and commissioning. The FPE’s credentials and compliance attestation must be submitted with the proposal.
- **Fire Alarm and Detection:** The system must be addressable, with all initiating devices (smoke, heat, manual pull stations) individually identified. The fire alarm control panel must be non-proprietary (e.g., Fire-Lite Alarms by Honeywell), located in a temperature-controlled enclosure accessible from outside, and integrated with a Monaco BTX radio transmitter system for mass notification, transmitting signals to the Fort Drum Fire Department.
- **Fire Suppression:** Automatic wet-pipe sprinkler systems throughout, new water main and services, locking post indicator valve (PIV), 5-inch Storz hose connections, and metal fire extinguisher cabinets per NFPA 10. All systems must be inspected, tested, and certified by the FPE, with government personnel witnessing final tests.
- **Site Utilities and Connections:** The contractor must tie into existing water (1-inch HDPE SDR-11), sewer (3-inch stub out), and electrical (50 amp service with 30-foot cord and twist lock outlet) services, ensuring all above-grade piping is insulated and heat-taped to prevent freezing.
- **Building Access and Safety:** Concrete stairs with 12-inch tread, 6x6 foot landing, 4000 PSI minimum concrete, aluminum railings with black finish, and aggregate subbase.
**Contracting Entity and Contact Information:**
- **Entity:** W6QM MICC-FT DRUM (Federal Office)
- **Primary Contact:** Kimberley Lawrence
- Email: [email protected]
- Phone: 315-772-8281
**Procurement Details:**
- **Notice Type:** Combined Synopsis/Solicitation
- **Set-Aside:** SBA (Small Business)
- **NAICS Code:** 321991 (Manufactured Home Manufacturing)
- **PSC:** 5450
- **Response Deadline:** January 14, 2026, 16:01 (amended from January 8, 2026, to allow additional time due to holidays)
- **Notice Status:** Active
- **Source:** BIDMATCH_SAM
- **URL:** [SAM.gov Opportunity](https://sam.gov/opp/de6353616ab54a6080d93cd32b42b04d/view)
**Special Considerations:**
- All fire protection and life safety systems must be designed, installed, and certified by a qualified FPE, with comprehensive documentation and government review at each stage.
- The contractor must provide detailed design plans, code compliance analysis, and as-built documentation, with extended review periods for engineered submittals (15 business days).
- All systems and installations must comply with the latest UFC and NFPA standards, and testing must be coordinated with government representatives.
**Summary for Contractors:**
This opportunity is ideal for contractors specializing in modular home manufacturing and installation, with proven expertise in fire protection engineering and compliance with federal building codes and standards. The scope encompasses full design, construction, utility integration, and commissioning of a high-quality, code-compliant modular home, with stringent requirements for fire safety and life safety systems. Contractors must demonstrate the ability to deliver a turnkey solution, including all required documentation, certifications, and government coordination, within the specified timeline and regulatory framework.