Tiny Home

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

W6QM MICC-FT DRUM

Contract Value

Not provided

Codes & Classification
Solicitation Number

W911S226U2310

NAICS

321991 - Manufactured Home (Mobile Home) Manufacturing

Classification Code

5450

Additional Details
Set Aside

SBA

Place of Performance

-

SourceSAM
The U.S. Army Mission and Installation Contracting Command at Fort Drum (W6QM MICC-FT DRUM) has issued a Combined Synopsis/Solicitation for the procurement of a prebuilt modular "Tiny Home" designed for four-season use, with comprehensive fire protection and life safety systems. This opportunity, classified under NAICS Code 321991 (Manufactured Home (Mobile Home) Manufacturing), is set aside for Small Business Administration (SBA) eligible contractors. **Purpose and Scope:** The primary objective of this procurement is to acquire a modular tiny home with a screened-in outdoor porch, intended for personnel housing or similar lodging facilities. The home must be prebuilt and delivered with all specified features, ensuring durability, comfort, and compliance with stringent fire protection and safety standards. The project encompasses not only the supply and installation of the home itself but also the integration of advanced fire alarm, detection, and suppression systems, as well as utility connections and structural supports. **Key Requirements and Deliverables:** - **Exterior Specifications:** - Maximum dimensions: 13 feet 8 inches by 39 feet 7 inches. - Standing seam metal roof (5:12 pitch, factory finish). - Engineered wood lap siding and trims with textured finish. - LED outdoor lighting near entryway. - Insulated single hung low E vinyl windows (no grid). - Lockable painted 6-panel steel entryway door with smart programmable lock. - Electrical panel box in NEMA-rated enclosure for 50 amp service. - Insulated skirting (R11 or greater) matching building siding, with access door for underbelly. - **Interior Specifications:** - Kitchen: 18 CF stainless steel refrigerator, full-size gas range, space saver microwave, single bowl stainless steel sink, box-built cabinets, soft-close drawers, tile backsplash, granite countertops. - Bathroom: Tile shower with glass door, china lavatory sink, comfort height toilet, rainfall and handheld shower heads, accessories. - HVAC: Fully electric split system units for heating/cooling in master bedroom and living area. - Finishes: Sealed interior walls and doors, wood blinds, smooth finished ceiling (9-10 feet), drywall with luan backer, vinyl plank flooring, solid wood trim. - Furniture: Sectional sofa, beds and mattresses for bunk and master rooms, wall-mounted TVs, ceiling fan, built-in dressers, USBC outlets, nightstands. - Utilities: On-demand gas water heater, standard manifold plumbing, electrical package for 50 amp service, deluxe LED lighting. - **Fire Protection and Life Safety:** - Complete fire sprinkler and alarm systems, designed and installed per UFC 3-600-01, UFC 4-021-01, NFPA 13R, NFPA 24, NFPA 70, NFPA 72, NFPA 101, NFPA 90A, NFPA 10, and referenced standards. - Fire Protection Engineer (FPE) involvement required throughout design, construction, and commissioning. FPE must be a registered P.E. with NCEES fire protection exam and at least 5 years’ experience. - Submission of FPE credentials and compliance letter with professional stamp/signature. - Engineered and stamped plans for fire protection, alarm, and suppression systems, with government review periods. - Addressable fire alarm and mass notification system, including Monaco BTX radio transmitter, control panel, annunciator, emergency lights, detectors, alarms, and gas shut-off. - Testing and certification of all fire protection systems, witnessed by government personnel. - **Site and Utility Connections:** - Building supports: CMU block piers with I-beams, anchored to existing reinforced concrete slab. - Stairs: Concrete stairs with 12-inch tread, 6x6 foot landing, aluminum railings, 4000 PSI concrete, aggregate subbase. - Water: Tie-in to 1-inch HDPE SDR-11 stub out, insulated and heat-taped piping. - Sewer: Tie-in to 3-inch stub out, insulated piping. - Electrical: Tie-in to existing 50-amp service with 30-foot cord and twist lock outlet. **Contracting Entity and Contact Information:** - **Entity:** W6QM MICC-FT DRUM (Federal Office) - **Primary Contact:** Carrie Lawton - Email: [email protected] - Phone: 315-772-1065 **Procurement Details:** - **Type:** Combined Synopsis/Solicitation (active) - **Set-Aside:** SBA (Small Business) - **NAICS:** 321991 (Manufactured Home Manufacturing, 2022) - **PSC:** 5450 - **Response Deadline:** January 14, 2026, 16:01 (amended from January 8, 2026, to allow for holiday schedules) - **Notice URL:** [SAM.gov Opportunity](https://sam.gov/opp/aa77a50788b24cddb289c5cccdbc48a3/view) **Special Considerations:** - All fire protection and life safety systems must be designed, installed, and certified by qualified professionals, with extensive documentation and government review. - The contractor must provide a comprehensive furniture package and ensure all utility connections are properly insulated and protected against freezing. - The project requires close coordination with government representatives for testing, inspections, and final acceptance. **Constant Elements Over Contract Lifecycle:** - Compliance with specified codes and standards for fire protection and life safety. - Involvement of a qualified Fire Protection Engineer throughout all phases. - Delivery of a fully functional, code-compliant modular home with all specified features and systems. - Ongoing coordination with the contracting office and adherence to government review and approval processes. This opportunity is well-suited for contractors experienced in modular home manufacturing, fire protection system design and installation, and federal construction standards. Interested parties should review the full solicitation and ensure they meet all technical, professional, and set-aside requirements before submitting a proposal.