Tiny Home
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
W6QM MICC-FT DRUM
Contract Value
Not provided
Codes & Classification
Solicitation Number
W911S226U2311
NAICS
321991 - Manufactured Home (Mobile Home) Manufacturing
Classification Code
5450
Additional Details
The U.S. Army, through the Mission and Installation Contracting Command at Fort Drum (W6QM MICC-FT DRUM), has issued a Combined Synopsis/Solicitation for the procurement of a prebuilt modular tiny home, classified under NAICS Code 321991 (Manufactured Home (Mobile Home) Manufacturing). This opportunity is set aside for Small Business Administration (SBA) eligible contractors, with responses due by January 14, 2026, at 16:01, following an amendment to extend the deadline due to the holiday period.
The scope of this procurement encompasses the design, manufacture, delivery, and installation of a modular home intended for four-season use, with strict dimensional requirements: the exterior must not exceed 13 feet 8 inches by 39 feet 7 inches. The home must feature a screened-in outdoor porch serving as the main entrance, and be constructed to high standards of durability, energy efficiency, and occupant comfort.
Key exterior requirements include a standing seam metal roof with a 5:12 pitch and factory-applied finish, engineered wood lap siding and trims with textured finish, LED outdoor lighting near the entryway, insulated single-hung low-E vinyl windows, and a lockable six-panel steel entry door equipped with a programmable smart lock. The building must be skirted with R11 or greater insulation, matching the siding and fully covering the underside, with an access door for underbelly maintenance.
Interior specifications are comprehensive, requiring a fully equipped kitchen (including an 18 CF stainless steel refrigerator, full-size gas range, space-saver microwave, single-bowl stainless steel sink, custom cabinetry, soft-close drawers, tile backsplash, and granite countertops), a full bathroom (with tile shower, glass door, rainfall and handheld shower heads, comfort-height toilet, and quality fixtures), and robust climate control via split system units for both the master bedroom and living area. The home must feature smooth-finished ceilings (9-10 feet), vinyl plank flooring, solid wood trim, and furniture packages for all living and sleeping areas, including beds, dressers, nightstands, sectional sofa, and wall-mounted TVs. Additional amenities include ceiling fans, USB-C outlets, and built-in storage.
A critical component of the project is the design and installation of comprehensive fire protection and life safety systems. The contractor must provide all materials, equipment, and labor for a complete and operable fire sprinkler and alarm system, in full compliance with the latest editions of UFC 3-600-01, UFC 4-021-01, NFPA 13R, NFPA 24, NFPA 70, NFPA 72, NFPA 101, NFPA 90A, NFPA 10, and related standards. The fire protection design must be overseen by a qualified Fire Protection Engineer (FPE)—a registered professional engineer with at least five years of dedicated fire protection experience and NCEES certification. The FPE is responsible for all aspects of code analysis, system design, multi-discipline review, construction inspection, and commissioning, and must submit credentials and compliance documentation with the proposal.
Deliverables include engineered and stamped plans and specifications for fire alarm and suppression systems, code compliance documentation, life safety plans, hydraulic analyses, and all required submittals for government review. The fire alarm system must be addressable, with mass notification capability, and transmit signals to the Fort Drum Fire Department. The suppression system must include a new water main, post indicator valve, wet-pipe sprinklers, and fire department connections, all installed per NFPA and UFC requirements. Testing and commissioning of all systems must be witnessed by government personnel, with test reports and as-built documentation provided post-construction.
Site work includes constructing building supports (CMU piers with I-beams anchored to a reinforced concrete slab), supplying and installing concrete stairs with aluminum railings, and connecting to existing water, sewer, and electrical services. All above-grade piping must be insulated and heat-taped to prevent freezing, and electrical connections must accommodate a 50-amp service.
This procurement is managed by Carrie Lawton ([email protected], 315-772-1065), and full details are available on SAM.gov under Opportunity ID c49ae8ce53f04a4bad2cbecbbb366526. Contractors should carefully review the requirements for modular home construction, fire protection engineering, and site integration to ensure alignment with their capabilities and experience in delivering turnkey housing solutions for federal clients. The project’s technical rigor, especially regarding fire protection and life safety, will remain constant throughout the contract lifecycle, demanding sustained compliance and professional oversight.