J045--Newington Campus BEI Corrections Updated SOW

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

241-NETWORK CONTRACT OFFICE 01 (36C241)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24126Q0062

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Classification Code

J045

Additional Details
Set Aside

SDVOSBC

Place of Performance

Newington, Connecticut, UNITED STATES

SourceSAM
Documents3
The Department of Veterans Affairs (VA), through the VA Connecticut Healthcare System, is soliciting qualified contractors for the correction of safety deficiencies at the Newington Campus Boiler Plant, located at 555 Willard Avenue, Newington, Connecticut. This procurement, issued under Combined Synopsis/Solicitation number 36C24126Q0062, is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses (SDVOSBC) and falls under NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors). **Purpose and Scope** The primary objective of this contract is to address and rectify safety concerns identified during a recent inspection of the Newington Campus Boiler Plant by the Boiler Efficiency Institute, Inc. (BEI). These corrections are essential to ensure ongoing compliance with VA Directive 1810 and all applicable codes, regulations, and standards governing boiler plant operations. The intended outcome is to maintain the safe, reliable, and code-compliant operation of the facility’s boilers, thereby supporting the VA’s mission to provide a secure environment for patients, staff, and visitors. **Key Requirements and Objectives** The scope of work encompasses a comprehensive range of corrective actions for Boilers #1 and #2, including but not limited to: - Replacement and adjustment of various fuel gas pressure cutoff switches, combustion air proving switches, purge airflow proving switches, and low fire proving switches. - Replumbing and retesting of switches to ensure proper operation and compliance with testing manuals. - Replacement of control panel-mounted draft gauges for furnace pressure, draft, and flue gas outlet pressure. - Replacement of leaking automatic pilot fuel gas shutoff valves and solenoid vent valves. - Adjustment or replacement of furnace pressure interlocks and verification of isolation valve positions. - General site corrections such as testing and verifying water relays, replacing high-water-level alarms, and installing new probe assemblies. - Installation of a Cross Boiler SCADA HMI system with plant trend functions. - Coordination of all work to minimize operational impact, including daily check-ins with the Boiler Plant Supervisor and submission of a final comprehensive report detailing repairs and testing. Boiler #3 is currently out of service and does not require corrective action. **Technical and Personnel Qualifications** Eligible bidders must have a field service representative located within 100 miles of the Newington Campus. The prime contractor and any subcontracted labor must meet this requirement. Contractors must demonstrate at least three years of relevant experience with commercial and industrial steam boiler systems, including installation, repair, inspection, cleaning, calibration, and testing. Personnel must possess industry-standard certifications, including current OSHA certification (minimum 10 hours, 30 hours preferred), and welders must hold R-stamp certification. Documentation of technical training and certifications must be submitted for review and acceptance prior to commencement of work. **Compliance and Safety Considerations** All work must adhere to VA Connecticut Healthcare System policies regarding confined space entry, Lock Out Tag Out (LOTO) procedures, and hot work permits. Contractors are required to follow VA Medical Center Policy 138-075 for LOTO and Standard Operating Procedure SOP-SO-010 for confined space entry. The use of cast iron fittings and pipe components is prohibited except in specific, approved instances. All new steam and condensate lines must be Schedule 80, with double in-series valve systems and welded connections preferred. Repairs and modifications must comply with ASME and NBIC standards, and all welding must meet ASME Section V and VIII requirements. **Deliverables and Documentation** Contractors are responsible for providing a project schedule, work procedures, inspection and testing protocols, safety documentation, weld procedures, and certifications for review prior to starting work. Upon completion, a final documentation report—including all tests, photographs, and corrections—must be submitted within fourteen business days. Material certifications for replacement parts and waste manifests are required. All records generated under this contract are the property of the U.S. Government and must be managed in accordance with federal records management policies. **Administrative and Site Instructions** Contractor personnel must comply with VA Security Management Program requirements, including obtaining temporary identification badges and adhering to site access protocols. Smoking, vaping, and tobacco use are strictly prohibited on VA grounds. Photography is not permitted without written authorization from the contracting officer. Parking and material storage must be confined to designated areas, and all operations must minimize disruption to ongoing facility activities. **Contracting Entity and Contact Information** This opportunity is managed by the 241-Network Contract Office 01 (36C241), a federal office of the VA. The primary point of contact is Nathan Langone, who can be reached at [email protected] or 603-624-4366. **Procurement Details** - Notice Type: Combined Synopsis/Solicitation - Set-Aside: Service-Disabled Veteran-Owned Small Business (SDVOSBC) - NAICS Code: 238220 (Plumbing, Heating, and Air-Conditioning Contractors) - Product Service Code: J045 - Place of Performance: Newington, Connecticut, USA - Period of Performance: 45 days from contract award and Notice to Proceed - Response Deadline: December 19, 2025, 22:12 EST - Notice URL: [SAM.gov Opportunity](https://sam.gov/opp/3ac573b43abe48b7851e317e87fc5345/view) **Summary** This contract represents a critical opportunity for qualified SDVOSBC contractors with expertise in industrial boiler plant safety corrections, compliance, and maintenance. The work requires a high level of technical proficiency, strict adherence to safety and regulatory standards, and the ability to coordinate effectively with VA personnel. Contractors must be prepared to deliver comprehensive documentation, maintain rigorous records management, and ensure all work is performed to the highest standards of quality and safety. Interested parties should review the full solicitation and submit responses by the specified deadline.