Engineering Services to Conduct ARC Fault Assessment in FEMA Region 1 Federal Regional Center

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

REGION 1

Contract Value

Not provided

Codes & Classification
Solicitation Number

70FBR125Q00000017

NAICS

541330 - Engineering Services

Classification Code

H259

Additional Details
Set Aside

SBA

Place of Performance

Maynard, Massachusetts, UNITED STATES

SourceSAM
Documents3
The Department of Homeland Security (DHS), through the Federal Emergency Management Agency (FEMA) Region 1, is soliciting qualified small businesses to provide specialized engineering services for an ARC Fault Assessment at the Federal Regional Center (FRC) located in Maynard, Massachusetts. This procurement is issued as a combined synopsis/solicitation under a firm-fixed-price contract structure, with the intent to enhance electrical safety and compliance within the facility. The primary objective of this requirement is to conduct a comprehensive ARC Fault Assessment to evaluate workers’ potential exposure to ARC Flash Energy. The selected contractor will be responsible for developing safe working practices, establishing appropriate protection boundaries, and recommending suitable Personal Protective Equipment (PPE) for personnel operating within the FRC building. The assessment will specifically address the unique characteristics of the facility’s Uninterruptible Power Supply (UPS) system and related electrical infrastructure, as detailed in the attached Statement of Work (SOW) and supporting documentation. Key deliverables include a thorough technical analysis of ARC flash hazards, clear recommendations for mitigation strategies, and documentation that supports the development of safe operational protocols. The contractor’s findings will directly inform FEMA’s efforts to maintain a safe working environment and ensure compliance with relevant safety standards. This opportunity is set aside exclusively for small businesses under the SBA program, as indicated by the set-aside type. The applicable North American Industry Classification System (NAICS) code is 541330 (Engineering Services), and the Product Service Code is H259. Only offerors with an active registration in the System for Award Management (SAM) at the time of submission will be considered eligible for award. Interested contractors are required to submit a complete proposal that demonstrates their technical approach and understanding of the requirements outlined in the SOW. Proposals must include a detailed, itemized quote along with essential business information such as DUNS Number and/or Cage Code, business name, address, point of contact, and contact details. Additionally, contractors must provide the Reps and Certs report from SAM.gov and agree to hold pricing for 30 calendar days from the quote submission deadline. A site visit is scheduled for Monday, August 25, 2025, at 11:00 AM EST, offering prospective offerors the opportunity to familiarize themselves with the facility and clarify any technical aspects of the requirement. Attendance must be confirmed via email to [email protected] by 9:00 AM EST on the same day. All proposals are due no later than 3:00 PM EST on Wednesday, August 27, 2025. Submissions should be sent electronically to both Anhur Maklef ([email protected]) and Karley Hoyt ([email protected]). The contracting office will evaluate proposals based on compliance with submission and evaluation requirements, with award made to the offeror whose price is determined fair and reasonable. The contracting entity for this procurement is FEMA Region 1, a federal office under the Department of Homeland Security. The primary point of contact for this solicitation is Anhur Maklef (202-718-7118, [email protected]), with Karley Hoyt serving as the secondary contact. This procurement represents a critical initiative to ensure the safety and operational integrity of FEMA’s Region 1 Federal Regional Center. Contractors with demonstrated expertise in engineering services, particularly in ARC flash hazard analysis and electrical safety, are encouraged to review the full solicitation and associated attachments for further details.