Multnomah Falls Lodge - Walk in cooler Insulation Upgrade

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

USDA-FS, CSA NORTHWEST 6

Contract Value

Not provided

Codes & Classification
Solicitation Number

1240BH25Q0026

NAICS

236220 - Commercial and Institutional Building Construction

Classification Code

Z2AZ

Additional Details
Set Aside

SBA

Place of Performance

Corbett, Oregon, UNITED STATES

SourceSAM
The United States Department of Agriculture Forest Service (USDA-FS), through its Northwest 6 Contracting Office, has issued a presolicitation notice for a significant facilities upgrade at the historic Multnomah Falls Lodge in Corbett, Oregon. This project, identified under procurement number 1240BH25Q0026, seeks to replace the existing walk-in cooler, freezer, and produce cooler within the lodge’s kitchen facilities. The primary objective is to ensure the continued safe and efficient operation of food storage at this high-traffic, historic site. The scope of work encompasses the complete demolition and removal of the three existing refrigeration units, followed by the furnishing and installation of new, fully functional walk-in cooler, walk-in freezer, and produce cooler units. The contractor will be responsible for providing all necessary labor and materials to achieve a turnkey installation, adhering strictly to all applicable laws and regulations. Notably, all electrical work must be performed by a licensed electrician in the state of Oregon, and the contractor is required to secure all relevant permits prior to commencement. All newly installed equipment must carry a minimum one-year warranty from the date of start-up, ensuring reliability and accountability post-installation. A critical aspect of this project is the integration with the existing wet/glycol fire suppression system, which currently serves the cooler and freezer areas. The contractor must replace the four sprinkler heads within the walk-in units and two additional heads in the ceiling space above, including system drawdown and restoration to operational status. Detailed as-built documentation for the fire suppression system will be provided. Additionally, after installation, the contractor is responsible for restoring any affected interior kitchen walls, floors, or ceilings to their original condition. The period of performance is tightly defined: demolition and installation activities may begin no earlier than October 1, 2025, and must be completed by February 28, 2026. Once the notice to proceed is issued, installation dates must be coordinated within 45 days, and the actual construction period is limited to a maximum of 12 calendar days. This schedule is designed to minimize disruption, as the lodge kitchen will remain operational throughout the project. The Multnomah Falls Co. Inc. (MFC), which operates the lodge under permit, will provide temporary cooler and freezer capacity during the replacement process. Close coordination with both MFC and the Contracting Officer is required to ensure business continuity. Contractors are expected to submit shop drawings, product data, ancillary equipment details, and anchoring methods for approval prior to construction. The provided contract drawings are conceptual and intended only to convey general layout and sizing; they are not to be used for construction purposes. The estimated magnitude of this construction effort is between $100,000 and $250,000. The procurement is classified under NAICS code 236220 (Commercial and Institutional Building Construction, 2022 version) and Product Service Code Z2AZ. The opportunity is set aside for SBA participants. It is important to note that this notice is informational only and does not constitute a request for quotes. The solicitation is being issued as a call request under an existing Blanket Purchase Agreement (BPA) on the Northwest Facilities Maintenance (FMAC) contract 1204M320Q0041. No new contractors are being added to the BPA at this time; only pre-qualified BPA holders are eligible to respond. Interested parties should direct any questions to the primary contact, Loren Mein, at [email protected] or by phone at 218-302-4863. Further details and updates can be found on the official SAM.gov opportunity page: https://sam.gov/opp/c02604d4a6f140688722914c219c8767/view. This project represents a critical infrastructure upgrade at a landmark federal facility, with a focus on quality, safety, and minimal operational disruption. Contractors with relevant experience in commercial refrigeration, fire suppression integration, and historic facility renovations will find this opportunity well-aligned with their capabilities, provided they are current BPA holders under the referenced agreement.