J065--MRI door replacement

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

241-NETWORK CONTRACT OFFICE 01 (36C241)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24125Q0781

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Classification Code

J065

Additional Details
Set Aside

SDVOSBC

Place of Performance

White River Junction, Vermont, UNITED STATES

SourceSAM
The Department of Veterans Affairs, through its 241-Network Contract Office 01, is soliciting quotations for the full replacement of the MRI door at the White River Junction VA Medical Center (VAMC) in Vermont. This procurement, identified under RFQ number 36C24125Q0781, is issued as a combined synopsis/solicitation for commercial services in accordance with FAR Subpart 12.6. The opportunity is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses (SDVOSBC), aligning with the VA’s commitment to supporting veteran entrepreneurs. **Purpose and Scope** The primary objective of this contract is to ensure the safe, compliant, and effective replacement of the MRI door at the White River Junction VAMC, located at 163 Veterans Drive, White River Junction, VT 05001. The existing door must be replaced with a new radiation-shielded door suitable for the MRI environment. The scope of work includes the removal of the current door, installation of the new shielded door, and reinstallation of existing hardware, which remains in good condition. Upon completion, the contractor is required to conduct a certified RF (radio frequency) test to verify the integrity of the shielding and ensure there are no leaks, thereby maintaining the safety and operational standards of the MRI suite. **Key Requirements and Deliverables** - **Door Replacement:** The contractor will provide all labor, materials, and expertise necessary for the full replacement of the MRI door, ensuring the new door meets radiation shielding specifications. - **Hardware Reinstallation:** Existing door hardware will be removed and reinstalled on the new door by the contractor. - **RF Testing:** A certified RF test must be performed post-installation to confirm the absence of leaks. The contractor is responsible for engaging certified personnel for this task. - **Site Coordination:** Work will be conducted in an active healthcare facility, requiring phased execution to minimize disruption to staff and patients. Infection control measures, as defined by the ICRA assessment, must be strictly observed. - **Schedule and Flexibility:** The period of performance is 45 days after receipt of order (ARO). Normal working hours are 7:30 AM to 4:30 PM, with flexibility for after-hours or weekend work to accommodate patient care schedules, subject to coordination with the VA Contracting Officer’s Representative (COR). - **Regulatory Compliance:** The contractor is responsible for all regulatory notifications and must comply with federal privacy, security, and records management requirements. All deliverables and records generated are the property of the U.S. Government. - **Liability:** The contractor is liable for any damages to persons or property resulting from their actions or negligence during the project. **Contracting Entity and Contact Information** - **Contracting Office:** 241-NETWORK CONTRACT OFFICE 01 (36C241), a federal office responsible for procurement activities within the VA network. - **Primary Point of Contact:** Kenya Mitchell, reachable at [email protected] or 860-666-6951. - **Solicitation Reference:** 36C24125Q0781 - **Place of Performance:** White River Junction VAMC, Vermont, USA **Classification Codes** - **NAICS Code:** 811310 – Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance - **Product Service Code:** J065 **Procurement Type and Special Considerations** This is a firm-fixed price contract opportunity, with all terms and conditions governed by the Federal Acquisition Circular 2023-01 and relevant FAR/VAAR clauses. The solicitation is inactive as of the notice status, but responses were due by September 8, 2025, at 5:00 PM EST, submitted electronically to the designated contracting officer. All offerors must be registered in the System for Award Management (SAM) and the VA’s VISTA system to be eligible for award. The procurement does not carry a Defense Priorities and Allocations System (DPAS) rating. **Evaluation and Submission Requirements** Offerors are required to submit a detailed quote, including a completed price schedule and a past performance worksheet listing three relevant contracts. Quotes must be logically assembled, indexed, and include the company name, date, and solicitation number on each page. Annual representations and certifications must be completed in SAM, and compliance with all applicable federal and agency policies is mandatory. **Constant Elements Throughout the Contract Lifecycle** - The contract will remain focused on the replacement and certification of the MRI door at the specified VA facility. - All work must adhere to federal privacy, security, and records management standards. - The contractor is responsible for coordination, safety, and compliance throughout the project duration. - The VA retains ownership of all deliverables and records produced under the contract. This opportunity is well-suited for SDVOSBCs with experience in specialized door installation, particularly in healthcare environments requiring radiation shielding and RF testing. Contractors must demonstrate the ability to manage projects in occupied medical facilities, coordinate with federal personnel, and comply with stringent regulatory requirements. For further details, interested parties should refer to the full solicitation and associated attachments available on SAM.gov under Opportunity ID 862460f9940f468daa175df63f3572a1.
Documents8