N063--N063 Cameras Replacement
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
241-NETWORK CONTRACT OFFICE 01 (36C241)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C24125Q0795
NAICS
561621 - Security Systems Services (except Locksmiths)
Classification Code
N063
Additional Details
Documents5
The Department of Veterans Affairs, through its 241-Network Contract Office 01, is soliciting proposals for a comprehensive replacement of the camera and access control systems at a residential facility located at 2-8 Cherry Street, Northampton, MA. This procurement, identified under solicitation number 36C24125Q0795 and classified under NAICS code 561621 (Security Systems Services, except Locksmiths), is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses (SDVOSBC).
**Purpose and Scope**
The primary objective of this contract is to replace the existing CCTV cameras and access control keypads throughout the residential facility, which comprises four units (2, 4, 6, and 8), each spanning three floors, totaling approximately 10,600 square feet. The intent is to upgrade the security infrastructure to ensure reliable, standalone electronic access and surveillance, tailored to the needs of a residential environment rather than a high-security federal installation.
**Key Requirements and Deliverables**
- **Camera Replacement:** The contractor is responsible for replacing approximately 36 existing cameras, with the potential addition of 2-4 new cameras to provide comprehensive coverage of the exterior parking area, backyard, and shed. The exact quantity and placement of new cameras are to be determined based on the contractor’s proposed solution, ensuring broad coverage as specified in the Performance Work Statement (PWS).
- **Access Control System:** Replacement of 28 existing card access readers (keypads) is required, with the removal of readers from bathrooms. The new system must support dual-factor authentication (card and unique PIN) for each user, with approximately 25 users (including residents and staff). The solution must be standalone, not integrated with VA Police or other VA campus security systems, and must not require recurring licensing or subscription fees.
- **Infrastructure and Installation:** Contractors should assume the need for new cabling to support the upgraded systems, as the status of existing low-voltage infrastructure is uncertain. All new line voltage wiring must be installed in conduit, and penetrations through walls, ceilings, or floors must be fire-stopped. The building features hard ceilings (gypsum wallboard and plaster) and wood-framed construction, with limited existing cable trays and pipe chases.
- **Head-End Equipment:** The head-end for both CCTV and access control will remain in the current office/closet space, which is the only secure area available. Contractors must account for equipment selection and layout to mitigate heat generation, as ventilation is limited.
- **System Features:** The upgraded systems must be physically hardwired, with no internet connectivity or wireless vulnerabilities (Bluetooth, Wi-Fi, etc.). Battery backup for card readers and cameras is required to support 4-8 hours of operation during power outages. The system must be self-sustaining, allowing VA staff to manage user profiles and access programming without external support.
- **Disposal and Transition:** All existing equipment must be removed and disposed of by the contractor, except for devices with volatile memory (e.g., DVRs), which will be turned over to the VA for secure destruction. The contractor is also responsible for providing a plan for migration of current users and credentials, if applicable.
**Contracting and Proposal Details**
- **Contract Type:** Firm fixed price, with award based on Lowest Price Technically Acceptable (LPTA) criteria.
- **Proposal Requirements:** Proposals must include a succinct concept and completion plan demonstrating compliance with the PWS, accompanied by a detailed cost breakdown. Technical solutions should be clearly described, with supporting documentation such as floor plans and device locations provided as attachments.
- **Site Visit:** A site visit was conducted on September 5, 2025. All relevant Q&A and sign-in sheets have been posted.
- **Performance Period:** The response deadline for proposals is September 23, 2025, at 4:00 PM. Requests for extensions have been considered; see amendments for updates.
- **Funding:** Fiscal Year 2025 funding is allocated for this project. The budget range is not disclosed.
- **Special Considerations:** The facility is a residential patient area, so after-hours access for installation is unlikely and must be coordinated as needed. The building dates to 1900, with some lead paint and limited asbestos-containing materials, though these are not anticipated to impact the scope of work.
**Contact and Reference Information**
- **Contracting Entity:** 241-Network Contract Office 01 (36C241), Federal Office
- **Primary Contact:** Sherrye Harris, [email protected], 774-826-3361
- **Place of Performance:** Northampton, MA, United States
- **Product Service Code:** N063 (Installation of Equipment – Alarm, Signal, and Security Detection Systems)
- **SAM.gov Opportunity ID:** a3c6bb500b97420d9dc3a60a91ac7957
- **Notice Source and Attachments:** Full details, including floor plans and images of existing equipment, are available on SAM.gov (https://sam.gov/opp/a3c6bb500b97420d9dc3a60a91ac7957/view).
**Summary for Contractors**
This opportunity is well-suited for SDVOSBCs with expertise in turnkey security system upgrades for residential healthcare environments. The scope requires a comprehensive approach to replacing and upgrading both CCTV and access control systems, with careful attention to infrastructure, user management, and compliance with VA requirements for standalone, non-networked solutions. Contractors must be prepared to assess existing conditions, propose robust solutions, and execute installation with minimal disruption to residents. All work must be performed in accordance with the PWS, and proposals should clearly demonstrate technical understanding, compliance, and cost-effectiveness.
Contractors are encouraged to review all posted attachments and Q&A for detailed site information and to ensure their proposals address all specified requirements and constraints.