C1DZ--442-25-002 SPS Renovation (VA-25-00099382)
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
NETWORK CONTRACT OFFICE 19 (36C259)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C25925R0117
NAICS
541330 - Engineering Services
Classification Code
C1DZ
Additional Details
Documents4
The Department of Veterans Affairs (VA), through its Network Contracting Office 19, has issued a presolicitation notice for the establishment of an Architect-Engineering (A-E) contract to support the SPS Renovation Project No. 442-25-002 at the Cheyenne VA Medical Center, located at 2360 East Pershing Blvd., Cheyenne, Wyoming 82001. This opportunity is exclusively set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), in accordance with VA’s Veterans First Contracting Program and relevant SBA regulations.
**Purpose and Scope**
The primary objective of this procurement is to secure comprehensive A-E services for the investigation, design, cost estimating, preparation of construction documents, and construction administration for the renovation of the Sterile Processing Services (SPS) and Sterile Processing Department (SPD) at the Cheyenne VAMC. The intended outcome is a fully compliant, operationally efficient, and modernized SPS/SPD facility that meets all current VA directives, industry standards, and applicable codes.
**Key Requirements and Expected Deliverables**
The selected A-E firm will be responsible for a broad range of design and investigative tasks, including but not limited to:
- Evaluation and design of the air handling unit (AHU) serving the SPS/SPD, ensuring compliance with temperature, humidity, air change rates, and pressure differential specifications.
- Assessment and recalculation of load capacities for existing VAV and exhaust fans, with replacement and ductwork modifications as necessary.
- Installation of digital pressure monitors in specified areas.
- Comprehensive evaluation of the current SPS/SPD layout to optimize equipment placement and workflow, ensuring regulatory compliance.
- Design and construction of an enclosed cart drying area on the clean side of the cart washer.
- Assessment and potential installation of a dedicated reverse osmosis (RO) system for the SPS area.
- Removal and replacement of flooring throughout the SPS/SPD with durable, easy-to-clean materials.
- Design and construction of a new ante room adjacent to the preparation area.
- Installation of automatic doors for the SPS decontamination area to support hands-free access and contamination control.
- Redesign and possible expansion of the decontamination ante room.
- Evaluation of the need for temporary SPS trailers during construction, including site selection and utility assessment.
- Installation of emergency lighting to meet life safety codes.
- Evaluation of the feasibility of adding a medivator to the SPS department.
All design work must encompass electrical, mechanical, civil, structural, and architectural components, with detailed system documentation. The A-E will conduct thorough investigations and verifications of the building areas involved, referencing original mechanical plans and additional documentation as needed. All aspects of the design must adhere to the latest VA Master Specifications, VA Design Standards, and relevant codes (NEC, NFPA, IBC, OSHA, ASME, and others).
**Design Criteria and Construction Administration**
The contract requires clear delineation of electrical terminations, compliance with fire barrier penetration standards, system testing and commissioning, integration of energy-efficient technologies, coordination of finishes with VA interior designers, and provision of testing and balancing parameters. Construction documents must be updated to reflect field changes and submitted in AutoCAD and PDF formats. The A-E will also provide direction for utility relocations and modifications.
Investigative services include submission of a bound report and electronic PDF detailing project pros and cons, preliminary cost estimates, and results from initial testing and investigations. The A-E will engage with medical center staff to assess current system performance and requirements, and conduct in-person inspections to inform phased design strategies.
**Evaluation Criteria**
Offerors will be evaluated based on the following criteria, in order of importance:
1. Specialized experience and technical competence in similar services, particularly SPS/SPD design and multi-phased hospital projects.
2. Professional qualifications of key personnel across relevant disciplines (architecture, interior design, structural, mechanical, electrical, plumbing).
3. Capacity to accomplish the work within required timeframes, including management of concurrent projects.
4. Past performance with government and private sector clients, focusing on cost control, quality, and schedule compliance.
5. Experience and qualifications of proposed personnel and their history of working together as a team.
6. Commitment to utilizing SDVOSB, VOSB, and other small businesses as subcontractors.
7. Experience in construction period services, including field inspections, submittal reviews, and support for contract changes.
Submission requirements include detailed SF-330 forms (Parts I and II), project examples, resumes, past performance documentation (CPARS or PPQs), and evidence of subcontracting commitments. All submissions must be electronic, with strict adherence to file format and size limitations.
**Contracting Entity and Contact Information**
- Contracting Office: Network Contracting Office 19 (36C259)
- Contracting Entity Type: Federal Office
- Primary Contact: Josiah Benton
- Email: [email protected]
- Phone: 303-712-5770
**Procurement Details and Special Considerations**
- NAICS Code: 541330 (Engineering Services), size standard $25.5 million.
- Product Service Code: C1DZ.
- Estimated construction magnitude: $5,000,000 to $10,000,000.
- Set-Aside: Total set-aside for certified SDVOSBs.
- Place of Performance: Cheyenne, WY.
- All offerors must be certified and listed in the SBA Veteran Small Business Certification Program database at the time of offer and award.
- Compliance with limitations on subcontracting and other SDVOSB program requirements is mandatory.
**Lifecycle Considerations**
Throughout the contract, the A-E firm will be expected to maintain compliance with all VA standards, codes, and reporting requirements, coordinate closely with the VA’s Contracting Officer’s Representative (COR), and ensure the medical center remains operational during construction. Regular schedule updates using Microsoft Project are required, and all documentation must be sufficiently detailed to support competitive construction bidding.
**Summary for Contractors**
This opportunity is well-suited for SDVOSB firms with demonstrated expertise in healthcare facility design, particularly in sterile processing environments, and experience managing complex, multi-phased renovation projects in operational hospital settings. Firms must possess strong technical qualifications, a proven track record of timely project delivery, and a commitment to supporting veteran-owned and other small businesses through subcontracting. The scope and requirements are comprehensive, demanding a multidisciplinary approach and rigorous adherence to VA and industry standards.
Interested and eligible firms should prepare and submit their SF-330 packages electronically to the designated contact by the specified deadline, ensuring all evaluation criteria and submission requirements are thoroughly addressed.
For further details and to access the full notice, visit: [SAM.gov Opportunity](https://sam.gov/opp/800d7dc5423d4c32b20ac474109aace4/view).